Commercial & Industrial · 30 kW – 2 MW
MTX-S60MTX Standard 60 · 60 kW
Commercial cabinet · 2 × 30 kW PM · MSME factory · hotel · hospital wing · 60 kVA DG replacement
Two 30 kW power modules in one MTX cabinet for 60 kW of bidirectional, isolated conversion. The workhorse for MSME factories, hotels and hospital wings that want demand-charge cuts and DG-hours reduction without a container footprint.
Full technical sheet.
Power conversion
- Configured power60 kW · 2 PMs
- Power module30 kW bidirectional, high-frequency isolated
- AC voltage range260–530 V · 3-phase + PE
- DC range150–1000 V (full power 300–1000 V)
- Peak PM efficiency≥ 95.5%
- Charging power factor≥ 0.99
- Backup transferAutomatic restart in ~30–40 s
- Parallel supportUp to 8 PMs off-grid · 60 PMs grid-tied
Battery
- Cell chemistryLiFePO4 (LFP)
- Cell platform3.2 V · 100 Ah
- Stored energySized to required backup duration
- Cycle capability~6,000 cycles*
Cabinet & environment
- ConstructionTwo-bay cabinet · battery bay + equipment bay
- Footprint (50 kW ref.)1,654 × 1,000 × 1,856 mm
- CoolingForced air
- Operating temp-40 °C → +70 °C (full rating to +55 °C)
- PM communicationCAN
Control & monitoring
- Battery managementIn-house TOBOR BMS
- Energy managementIn-house TOBOR EMS
- Dispatch modesPeak shaving · ToU shifting · Solar self-use · Backup reserve
- Site integrationGrid · Solar PV · DG · EV charging
- Remote accessCloud EMS dashboard · remote diagnostics
Catalogue values. *Cycle capability depends on depth of discharge, C-rate, temperature and end-of-life criterion. Peak PM efficiency is not whole-system round-trip efficiency. Usable energy and runtime depend on permitted DoD, conversion losses and auxiliaries. Final ratings and compliance follow the approved project-specific offer.
Where this size fits.
Peak-demand shaving
Clip maximum-demand peaks with EMS dispatch inside battery limits. Demand-charge savings are sized from your 15-minute interval data.
Solar self-consumption
Charge from surplus rooftop or ground-mount PV and dispatch it into evening and night shifts instead of exporting at low rates.
DG-hours reduction
Carry critical loads through outages and cut generator runtime. Battery capacity is sized to the outage profile and priority loads.
BESS-buffered EV charging
Run TOBOR DC fast chargers on a smaller grid connection — the battery covers the charging peaks, the EMS coordinates both.
Other commercial & industrial models.
Small MSME · clinic · retail · 30 kVA DG replacement
Commercial rooftop solar · critical loads · 3-phase unbalanced sites
Multi-line factory · cold chain · commercial complex · EV-charging buffer
Large MSME · 200-bed hospital · IT campus · 250 kVA DG replacement
Process industry · fleet depot · commercial campus · 500 kVA DG replacement
HT industrial consumer · data-centre campus · C&I solar park
Large HT consumer · industrial park · open-access solar · DCFC hub
Ready to size your project?
Share your interval load data, tariff and grid limits. Our engineers return a kW / kWh sizing, dispatch logic and a techno-commercial offer.
Request quote