Critical power. Zero diesel. Zero noise.
Hospitals can't afford 5-second DG warm-ups during a code-blue. 4-star hotels can't afford diesel smell drifting into the lobby. Infozeb BESS gives you sub-20 ms transfer and silent, fume-free 8-hour runtime — every day.
Hospitals · hotels · operating theatres · cold-chain
Diesel is the cheap option until it costs you a patient.
200-bed multi-specialty hospital · 240 kW critical load · 12 outages/month
| Cost line | Today | With Infozeb |
|---|---|---|
| Diesel fuel (DG running ~60 h/month) | ₹8.6L/yr | ₹0 |
| DG maintenance + AMC (240 kVA × 2 redundant) | ₹4.2L/yr | ₹0.5L/yr |
| CPCB CEMS instrumentation + reporting | ₹6L (one-time) + ₹1L/yr | — |
| UPS battery replacement (lead-acid, 4-yr cycle) | ₹3L/yr amortised | Replaced by BESS |
| Transfer-time risk (OT, ICU, MRI) | 5–10 sec DG ATS | <20 ms · zero process loss |
| Total annual outflow | ₹17L+ | ₹3L |
Annual savings
Payback in 3.5–4 years on IZ-240K-3P. The harder-to-quantify upside: zero risk of a half-second power gap during a procedure.
Why operators in this segment pick Infozeb.
Sub-20ms transfer for OT / ICU
Operating theatres, ventilators, MRI, cold-chain — none of them tolerate a 5-second DG warm-up. BESS islanding is faster than your existing UPS.
Silent operation
Under 50 dB. Guest-facing hotel zones stay quiet during outages. Hospital wards don't get a DG roar through the night.
Zero local emissions
No NO₂, no PM2.5, no diesel smell drifting through hotel lobbies or hospital corridors. Pollution Control Board audit risk eliminated.
Replaces lead-acid UPS too
Many hospitals run a separate UPS for critical loads. The BESS covers both UPS-class transfer and DG-class endurance — one platform, one warranty.
Pairs with critical-load segregation
Most hospitals already split critical (OT, ICU, lifts) vs non-critical (admin, F&B). BESS sits on the critical bus; existing DG can stay for non-critical multi-hour backup.
10-year warranty · field-replaceable
Cells warrantied for 10 years at 70%+ capacity. Modules are field-swappable so no single failure takes the entire system offline.
Pick the size, or let us pick for you.
The calculator selects automatically based on your bill and load. Or skim the picker below.
IZ-60K-3P
60 kW · 120 kWh
Boutique hotel · 3-star · 40-bed clinic · single OT
IZ-120K-3P
120 kW · 240 kWh
4-star hotel · 100-bed hospital · multi-specialty OT block
IZ-240K-3P
240 kW · 480 kWh
5-star hotel · 200-bed hospital · ICU + imaging + OT campus
IZ-480K-3P
480 kW · 960 kWh
Hospital network · resort property · multi-building campus
Questions, answered.
How does this compare to our existing UPS + DG combo?
Will the BESS handle MRI / CT load spikes?
What if we lose grid for 6+ hours?
Can we integrate the BESS alarms into our existing BMS?
What's the cost vs continuing with our current DG + UPS setup?
Your patients can't feel a 5-second outage. Neither should you.
220+ sites running · 14 MWh deployed · Made in Gurugram