Commercial & Industrial · 30 kW – 2 MW
MTX-H60MTX Hybrid 50 / 60 · 60 kW
Solar-hybrid cabinet · 50 / 60 kVA · Commercial rooftop solar · critical loads · 3-phase unbalanced sites
Solar + storage + backup in one cabinet. The MTX Hybrid integrates two MPPTs (38.4 kW each) and a built-in switching device for grid ↔ off-grid transfer in under 10 ms, with 100% unbalanced-load support on a 400/230 V four-wire output.
Full technical sheet.
AC & battery
- Rated / peak output50 / 60 kVA · peak 55 / 66 kVA
- Active power50 / 60 kW at unity PF
- Rated AC current73 A / 87 A
- AC output400 / 230 V · 3-phase 4-wire
- Grid voltage range-20% → +20%
- Battery window350–820 V (50 kVA) · 420–820 V (60 kVA)
- Max battery current150 A
- Mode transfer< 10 ms (PM specification)
- Unbalanced load100%
Solar integration
- PV inputs2 MPPTs · 38.4 + 38.4 kW
- MPPT window200–800 V
- PV start / max voltage250 V / 850 V
- Max PV current64 A + 64 A
- Off-grid parallelUp to 15 PMs
Environment
- Operating temp-30 °C → +60 °C (derates above 45 °C)
- PM coolingForced air · IP20 PM inside cabinet
- Battery chemistryLiFePO4 · 3.2 V 100 Ah · ~6,000 cycles*
- CommunicationEMS RS485 · battery CAN / RS485
Control & monitoring
- Battery managementIn-house TOBOR BMS
- Energy managementIn-house TOBOR EMS
- Dispatch modesPeak shaving · ToU shifting · Solar self-use · Backup reserve
- Site integrationGrid · Solar PV · DG · EV charging
- Remote accessCloud EMS dashboard · remote diagnostics
Catalogue values. *Cycle capability depends on depth of discharge, C-rate, temperature and end-of-life criterion. Peak PM efficiency is not whole-system round-trip efficiency. Usable energy and runtime depend on permitted DoD, conversion losses and auxiliaries. Final ratings and compliance follow the approved project-specific offer.
Where this size fits.
Peak-demand shaving
Clip maximum-demand peaks with EMS dispatch inside battery limits. Demand-charge savings are sized from your 15-minute interval data.
Solar self-consumption
Charge from surplus rooftop or ground-mount PV and dispatch it into evening and night shifts instead of exporting at low rates.
DG-hours reduction
Carry critical loads through outages and cut generator runtime. Battery capacity is sized to the outage profile and priority loads.
BESS-buffered EV charging
Run TOBOR DC fast chargers on a smaller grid connection — the battery covers the charging peaks, the EMS coordinates both.
Other commercial & industrial models.
Small MSME · clinic · retail · 30 kVA DG replacement
MSME factory · hotel · hospital wing · 60 kVA DG replacement
Multi-line factory · cold chain · commercial complex · EV-charging buffer
Large MSME · 200-bed hospital · IT campus · 250 kVA DG replacement
Process industry · fleet depot · commercial campus · 500 kVA DG replacement
HT industrial consumer · data-centre campus · C&I solar park
Large HT consumer · industrial park · open-access solar · DCFC hub