Replace your hub-site DG sets with solar + BESS.
Telecom hub, aggregation and cluster sites still lean on diesel. Fuel bills run into lakhs per site, theft is rampant, and CPCB CEMS now applies above 62.5 kVA. TOBOR MTX and PTX systems (30 kW–2 MW) plus site solar cut diesel runtime by 80–95% where one battery serves many radios. Single standalone towers sit below our range.
Hub, aggregation & cluster sites · 30 kW and up
Hub-site diesel costs you lakhs a year. Multiply by your hubs.
Illustrative hub / aggregation site · ~30 kW load · 6 h grid outage/day · 62.5 kVA DG today
| Cost line | Today | With TOBOR |
|---|---|---|
| Diesel fuel (~20,000 L/year at ₹100/L) | ₹20L/yr | ₹3L/yr (DG standby only) |
| DG O&M + AMC | ₹2L/yr | ₹0.4L/yr |
| Diesel pilferage / shrinkage | ₹1–2L/yr | Near zero |
| CPCB CEMS compliance (62.5+ kVA DG) | ₹2L (one-time) + audit | — |
| Total per-site outflow | ₹23–24L/yr | ₹3.4L/yr |
Annual savings
Illustrative — we model each site from its outage log and load. Multiply across your hub and aggregation sites. ESG-reporting bonus: 75–90% Scope-1 reduction at every converted site.
Why operators in this segment pick TOBOR.
Pilferage-proof storage
Diesel theft from rural sites is a chronic problem. Battery storage has no fluid to siphon. EMS detects any tamper attempt and alerts the NOC.
Remote NOC integration
Every TOBOR BESS streams to portal.infozeb.energy via cellular fallback. Existing OPCO NMS pulls state via SNMP or Modbus TCP.
Works with your −48 V DC plant
The BESS feeds the AC bus; your rectifier batteries keep radios up while it takes over — about 30–40 s automatic restart on MTX Standard, under 10 ms on MTX Hybrid. No waiting on a DG to crank.
Shelter-roof or ground-mount solar
Pair the BESS with solar on the shelter roof or adjacent land — the MTX Hybrid takes it directly on two 38.4 kW MPPTs. Charges the battery for free during the day.
CPCB CEMS for 60+ kVA DGs avoided
If your DG is above 62.5 kVA, you're paying ₹2L per site for CEMS instrumentation plus audits. Replacing the DG eliminates the regulatory exposure across the fleet.
ESG / Scope-1 reporting win
Telecom OPCOs reporting to TCFD or under SEBI BRSR see direct Scope-1 reduction. We provide site-level CO₂-offset reports per quarter.
Pick the size, or let us pick for you.
The calculator selects automatically based on your bill and load. Or skim the picker below.
MTX-S30
30 kW · sized to runtime
Multi-tenant macro / hub site · 15–25 kW load · DC plant batteries bridge the ~30–40 s restart
MTX-H60
50 / 60 kVA · sized to runtime
Aggregator site · 30–50 kW · < 10 ms transfer · built-in solar MPPT
PTX-250
250 kW · 257.2 kWh
MSC / switching centre · edge data centre · cluster microgrid
Standalone single-carrier towers (under 10 kW) are below TOBOR's commercial range — we work at hub, aggregation and cluster sites where one system serves many radios.
Questions, answered.
We have hundreds of hub sites. Can TOBOR actually scale that?
What happens if the BESS itself fails at a remote site?
Do you handle the solar installation too, or is that separate?
What's the typical OPCO pilot structure?
Does the BESS work in 50°C summer ambient at Rajasthan / Vidarbha sites?
Multiply the diesel savings across your hub sites.
In-house BMS, EMS & PCS · Made in Gurugram