Telecom towers in India still run on diesel. Per-site fuel costs ₹4–8L/yr, theft is rampant, and CPCB CEMS now applies above 62.5 kVA. Infozeb BESS + tower-mount solar drops diesel runtime by 80–95% per site — across a fleet of thousands.

Replicated across 460,000+ Indian tower sites

−85%
Diesel reduction per tower
₹5L/yr
Saved per site · typical
12 ms
Transfer time · zero call drops
Per-site economics

Tower diesel costs you ₹6L a year. Multiply by your fleet.

Typical tier-3 tower site · 7 kW load · 14 h grid outage/day · 60 kVA DG today

Cost lineTodayWith Infozeb
Diesel fuel (~6,000 L/year at ₹100/L)₹6L/yr₹0.9L/yr (DG standby only)
DG O&M + AMC₹0.9L/yr₹0.2L/yr
Diesel pilferage / shrinkage₹0.4–0.8L/yrNear zero
CPCB CEMS compliance (60 kVA DG)₹2L (one-time) + audit
Total per-site outflow₹7.5L/yr₹1.1L/yr

Annual savings

₹6.4L / site / year

Multiply across an OPCO fleet. A 1,000-site rollout reaches ₹64Cr/year in operating-cost savings. ESG-reporting bonus: 75–90% Scope-1 reduction.

Built for this

Why operators in this segment pick Infozeb.

Pilferage-proof storage

Diesel theft from rural sites is a chronic problem. Battery storage has no fluid to siphon. EMS detects any tamper attempt and alerts the NOC.

Remote NOC integration

Every Infozeb BESS streams to portal.infozeb.energy via cellular fallback. Existing OPCO NMS pulls state via SNMP or Modbus TCP.

Sub-20 ms transfer · zero call drops

Your radios and core BTS never see a power gap. DG ATS at 5–10 seconds drops active calls; BESS doesn't.

Tower-top or pole-mount solar

Pair the BESS with 5–15 kWp solar mounted on the tower or adjacent shelter roof. Charges the battery for free during the day.

CPCB CEMS for 60+ kVA DGs avoided

If your DG is above 62.5 kVA, you're paying ₹2L per site for CEMS instrumentation plus audits. Replacing the DG eliminates the regulatory exposure across the fleet.

ESG / Scope-1 reporting win

Telecom OPCOs reporting to TCFD or under SEBI BRSR see direct Scope-1 reduction. We provide site-level CO₂-offset reports per quarter.

Sizing guide

Pick the size, or let us pick for you.

The calculator selects automatically based on your bill and load. Or skim the picker below.

01

IZ-9K-3P

9 kW · 18 kWh

Standalone tower · 5–8 kW load · single carrier

02

IZ-30K-3P

30 kW · 60 kWh

Multi-carrier tower · 15–25 kW load · macro site

03

IZ-60K-3P

60 kW · 120 kWh

Aggregator / pole site · 30–50 kW · multi-tenant

04

IZ-120K-3P

120 kW · 240 kWh

BTS hub / IP-1 aggregation node · 60–100 kW

Frequently asked

Questions, answered.

We have 1,500+ sites. Can Infozeb actually scale that?
Today we deploy ~30 sites/month. With OPCO commitment we scale to 60–80/month within Q2 by adding a second assembly line in Gurugram and partner installer crews. Standardised site kits (cabinet + solar + cable harness) ship pre-packed. Most OPCOs deploy in 6–8 monthly tranches.
What happens if the BESS itself fails at a remote site?
Cloud EMS flags any anomaly before site impact. Field swap of a cell or BMS module is typically 2–3 hours. Mean Time Between Failures across our deployed fleet is currently >18 months. Spares pre-positioned at OPCO regional warehouses.
Do you handle the solar installation too, or is that separate?
We supply and commission the BESS. For solar, we partner with regional EPCs you may already use, or you can use your existing solar vendor — the BESS is solar-agnostic.
What's the typical OPCO pilot structure?
Start with 10–20 sites across 2–3 geographies (mix of urban, semi-urban, rural). 90-day data collection on diesel saved, transfer events, and pilferage incidents. Roll into a multi-tranche fleet rollout based on validated savings. We've completed 4 such pilot-to-fleet conversions.
Does the BESS work in 50°C summer ambient at Rajasthan / Vidarbha sites?
Yes. LiFePO4 cells operate to 55°C ambient with derating. The IZ-30K-3P and larger cabinets ship with thermal management (forced air at 7 kW, active cooling at 30 kW+). We have sites running through 48°C peaks in summer 2025 with no thermal events.

Multiply ₹6L per year across your tower fleet.

220+ sites running · 14 MWh deployed · Made in Gurugram