Cut your maximum demand bill 40%. Replace your diesel too.
Your factory pays two bills: the diesel bill (DG set) and the peak-demand bill (DISCOM). Infozeb BESS cuts both at the same time — and pays back in under 4 years on a typical MSME load.
Typical MSME factory · 60 kVA · 8 h/day
Diesel + demand charges. Both, gone.
Real MSME plant · 60 kVA load · 8 h/day · ₹9.50/unit tariff · ₹900/kVA demand charge
| Cost line | Today | With Infozeb |
|---|---|---|
| Diesel fuel (17,520 L/yr at ₹100/L) | ₹17.5L | ₹0 |
| DG maintenance + oil + AMC | ₹2.5L | ₹0.35L |
| CPCB CEMS instrumentation + audit | ₹2L (one-time) + ₹50k/yr | — |
| Peak demand charge (₹900/kVA · 60 kVA) | ₹6.5L/yr | ₹3.9L/yr |
| Energy charge (peak-hour units) | ₹12L/yr | ₹7.2L/yr |
| Total annual outflow | ₹40–43L | ₹11–12L |
Annual savings
Payback in 3–4 years on IZ-60K-3P + 80 kWp solar. After year 4, the savings are pure margin.
Why operators in this segment pick Infozeb.
Demand-charge shaving
EMS automatically discharges the battery during peak-demand windows. Most MSME factories see 30–45% reduction in monthly demand charge alone.
Solar self-consumption
Pair with rooftop solar to charge the battery for free. ₹2–3/unit running cost vs ₹9–10/unit grid + ₹18+/unit diesel.
Sub-20ms transfer
When the grid drops, your machinery doesn't notice. No 5–10 second DG warm-up. No process interruption, no scrap.
CPCB CEMS compliance avoided
DGs above 62.5 kVA need ₹2–4L in monitoring instrumentation plus ongoing audits. Replace the DG and the requirement goes away.
Same warranty as utility-scale
10-year cell warranty, 5-year PCS warranty. Field-replaceable modules. Cloud monitoring on every unit.
MNRE & SIDBI finance
C&I CAPEX subsidies (20–30% in tier-2/3) plus SIDBI/NABARD green loans for the balance. We help structure the project paperwork.
Pick the size, or let us pick for you.
The calculator selects automatically based on your bill and load. Or skim the picker below.
IZ-30K-3P
30 kW · 60 kWh
Small MSME unit · 30 kVA DG replacement · single shift
IZ-60K-3P
60 kW · 120 kWh
Mid MSME plant · 60 kVA DG · 2-shift operations
IZ-120K-3P
120 kW · 240 kWh
Multi-line factory · 100–125 kVA DG · 3-shift continuous
IZ-240K-3P
240 kW · 480 kWh
Large MSME · 200–250 kVA DG · heavy machinery / kilns
Questions, answered.
Can we keep the DG as backup and use the BESS primarily?
Will the BESS interrupt three-shift production during install?
What's the payback on demand-charge shaving alone (no DG replacement)?
Can the EMS integrate with our existing SCADA / MES?
What's the noise and footprint of a 60 kW cabinet?
Stop burning diesel. Start cutting demand charges.
220+ sites running · 14 MWh deployed · Made in Gurugram